{"id":42767,"date":"2019-09-23T10:09:38","date_gmt":"2019-09-23T01:09:38","guid":{"rendered":"https:\/\/www.decoboco.info\/en\/?p=42767"},"modified":"2026-09-24T13:45:14","modified_gmt":"2026-09-24T04:45:14","slug":"gsx1100s-inspection-mystery-fuse-blowing","status":"publish","type":"post","link":"https:\/\/www.decoboco.info\/en\/20190923\/everyday-events\/gsx1100s-inspection-mystery-fuse-blowing","title":{"rendered":"GSX1100S Inspection: Mystery Fuse Blowing"},"content":{"rendered":"\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1280\" height=\"854\" src=\"https:\/\/www.decoboco.info\/wp-content\/uploads\/2019\/09\/DSC_0666.jpg\" alt=\"\" class=\"wp-image-42760\"\/><figcaption>    <\/em><br><br>What a clean GSX1100S! The Katana really looks sharp with that black frame. <br>The owner came in for an inspection and to troubleshoot a mysterious fuse that keeps blowing. <br> <\/figcaption><\/figure>\n\n\n\n<!--more-->\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1280\" height=\"853\" src=\"https:\/\/www.decoboco.info\/wp-content\/uploads\/2019\/09\/DSC01661.jpg\" alt=\"\" class=\"wp-image-42761\"\/><figcaption>2. The signal fuse blows intermittently\u2014sometimes it happens when the engine revs up. <br>When I heard that, I thought, &#8220;How would anyone figure that out?&#8221; but I checked the manual anyway. <br><br>Before the fuse blows, I check whether <br>12V is grounding somewhere <br>or if there&#8217;s an overload exceeding 10A. <br>If the ground connection is loose, I set aside the main harness issue for now. <br><br>The image shows what the power supply looks like. When you really can&#8217;t figure it out, disconnecting the supply source is an option too. (Be careful\u2014some circuits won&#8217;t work if you disconnect them.) The process of elimination is the better approach. <\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1280\" height=\"853\" src=\"https:\/\/www.decoboco.info\/wp-content\/uploads\/2019\/09\/DSC01655.jpg\" alt=\"\" class=\"wp-image-42762\"\/><figcaption>The owner asked if it started after the turn signals were replaced, so I checked the area around them. Everything was installed cleanly, so I made a small adjustment and moved on. <\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1280\" height=\"853\" src=\"https:\/\/www.decoboco.info\/wp-content\/uploads\/2019\/09\/DSC01660.jpg\" alt=\"\" class=\"wp-image-42763\"\/><figcaption>Here&#8217;s what I found: the horn wire was touching the engine. <br>The horn vibrated with the engine, and occasionally it would rub and the insulation would wear away\u2014bad timing and pop! <br>That&#8217;s how it happened. <br><br>With a horn involved, you could say it was a real &#8220;horn-to-be-reckoned-with&#8221; learning experience. <br><br>I suddenly remembered a past weird case. <br>I think troubleshooting like this is better done without complaining and just using the process of elimination. I recalled a Harley that came in with a mystery fuse\u2014or rather, a mystery breaker that kept tripping. <br><br>It came in for inspection (naturally, the owner rode it in). After the headlight tester, the next morning I was thinking about loading it on the truck\u2014I went to start the engine and nothing lit up. The breaker had tripped. <br>I was seriously stumped. I&#8217;d already loaded another bike. <br><br>To sum it up: <br>\u2022 The owner had recently had the harness replaced at a specialty shop <br>\u2022 They rode it in <br>\u2022 Only the headlight tester was connected <br>\u2022 I pushed the seat and backed the bike up <br><br>Thinking about what was different from normal riding, I figured it might be around the seat area, so I looked closely at the wiring there and found it: <br>a single wire sticking out of the heat shrink tubing like an old man&#8217;s nose hair. <br>That one wire was touching the frame when the seat was pushed, and that was the cause. That&#8217;s the experience I had. <br><br>It&#8217;s not exactly a cautionary tale, but seeing that made me think, &#8220;That could be me tomorrow,&#8221; and I learned from it. <br><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1280\" height=\"853\" src=\"https:\/\/www.decoboco.info\/wp-content\/uploads\/2019\/09\/DSC01658.jpg\" alt=\"\" class=\"wp-image-42764\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1280\" height=\"853\" src=\"https:\/\/www.decoboco.info\/wp-content\/uploads\/2019\/09\/DSC01657.jpg\" alt=\"\" class=\"wp-image-42765\"\/><figcaption>After that, I checked the entire circuit path and we were done. <br>It should be fine now. Honestly, it&#8217;s easier to diagnose when fuses blow repeatedly. <br><br>It&#8217;s handy to keep a test fuse like this on hand. <br><a href=\"https:\/\/www.amazon.co.jp\/%E3%82%AD%E3%82%B8%E3%83%9E-Kijima-%E3%83%92%E3%83%A5%E3%83%BC%E3%82%BA%E3%83%96%E3%83%AC%E3%83%BC%E3%82%AB%E3%83%BC-1%E5%80%8B%E5%85%A5%E3%82%8A-304-7084\/dp\/B00J2O5HW6\/ref=pd_lpo_sbs_263_t_0?_encoding=UTF8&amp;psc=1&amp;refRID=Y7ED9R6W40D6JR5CTC05\">Kijima Fuse Breaker Flat Type 10A Universal 1 Piece 304-7084 <\/a><br><br><img decoding=\"async\" width=\"150\" height=\"150\" class=\"wp-image-42766\" style=\"width: 150px;\" src=\"https:\/\/www.decoboco.info\/wp-content\/uploads\/2019\/09\/31brGU-HTIL._AC_UL160_SR160160_.jpg\" alt=\"\" srcset=\"https:\/\/www.decoboco.info\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/31brGU-HTIL._AC_UL160_SR160160_.jpg 160w, https:\/\/www.decoboco.info\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/31brGU-HTIL._AC_UL160_SR160160_-150x150.jpg 150w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":42760,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"pochipp_cv_data":"","swell_btn_cv_data":"","footnotes":""},"categories":[1924],"tags":[162,65,122],"class_list":["post-42767","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-everyday-events","tag-electric","tag-gsx","tag-vehicle-inspection"],"_links":{"self":[{"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/posts\/42767","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/comments?post=42767"}],"version-history":[{"count":0,"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/posts\/42767\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/media\/42760"}],"wp:attachment":[{"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/media?parent=42767"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/categories?post=42767"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.decoboco.info\/en\/wp-json\/wp\/v2\/tags?post=42767"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}